{"product_id":"franklin-electric-20xc1-05p4-2w115-1-2-hp-115v-septic-pump","title":"Franklin Electric 20XC1-05P4-2W115, 1\/2 HP, 115V, Septic Pump","description":"\u003cdiv class=\"septicstop-product-content\"\u003e\n\u003c!-- QUICK SELLING POINTS --\u003e\n\u003cdiv style=\"background: #f7f7f7; border: 1px solid #e5e5e5; border-radius: 8px; padding: 18px 20px; margin: 0 0 25px 0;\"\u003e\n\u003cp style=\"margin: 0 0 10px 0; font-size: 18px;\"\u003e\u003cstrong\u003eHigh-head bottom-suction effluent pump designed for maximum drawdown in septic, cistern, and filtered-effluent applications.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 6px 0;\"\u003e✓ Genuine Franklin Electric C1 Series pump\u003c\/p\u003e\n\u003cp style=\"margin: 6px 0;\"\u003e✓ 1\/2 HP, 115V, single-phase motor\u003c\/p\u003e\n\u003cp style=\"margin: 6px 0;\"\u003e✓ 20 GPM rated flow with up to 25 GPM maximum flow\u003c\/p\u003e\n\u003cp style=\"margin: 6px 0;\"\u003e✓ High-head 5-stage design with 170 ft shutoff head\u003c\/p\u003e\n\u003cp style=\"margin: 6px 0;\"\u003e✓ Bottom suction for maximum tank drawdown\u003c\/p\u003e\n\u003cp style=\"margin: 6px 0;\"\u003e✓ Built-in removable check valve\u003c\/p\u003e\n\u003cp style=\"margin: 15px 0 0 0;\"\u003e\u003cstrong\u003eNot sure this is the right pump?\u003c\/strong\u003e Call us at \u003ca href=\"tel:+19408284004\"\u003e940-828-4004\u003c\/a\u003e or email \u003ca href=\"mailto:support@septicstop.com\"\u003esupport@septicstop.com\u003c\/a\u003e before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- FITMENT \/ APPLICATION --\u003e\n\u003ch2\u003eIs the Franklin 20XC1 the Right Pump for My Septic System?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFranklin Electric 20XC1-05P4-2W115\u003c\/strong\u003e is a \u003cstrong\u003e1\/2 HP, 115V high-head submersible pump\u003c\/strong\u003e designed for filtered effluent, gray water, cistern, and other applications where significant pressure and maximum tank drawdown are required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommon applications include:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFiltered septic effluent pumping\u003c\/li\u003e\n\u003cli\u003eAerobic treatment system pump tanks\u003c\/li\u003e\n\u003cli\u003ePressure-distribution septic systems\u003c\/li\u003e\n\u003cli\u003eCistern tanks\u003c\/li\u003e\n\u003cli\u003eGray water pumping\u003c\/li\u003e\n\u003cli\u003eWater reclamation systems\u003c\/li\u003e\n\u003cli\u003eRainwater catchment pumping\u003c\/li\u003e\n\u003cli\u003eAgricultural and livestock water applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"border-left: 4px solid #333; background: #fafafa; padding: 14px 18px; margin: 20px 0;\"\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e Do not select a replacement pump based on horsepower or nominal GPM alone. Verify the required flow rate, total dynamic head, voltage, discharge size, control method, and treatment-system requirements before ordering.\u003c\/div\u003e\n\u003cp\u003eIf you are replacing an existing pump, send us the model number from the old pump or a photo of the pump label and we can help you determine whether the Franklin 20XC1 is the appropriate replacement. \u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003ePlease Note: When replacing a pump, the pump float must also be replaced. We will not warranty these water pumps if the float is not purchased. \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- DESCRIPTION --\u003e\n\u003ch2\u003eFranklin Electric 20XC1 High-Head Effluent Pump\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFranklin Electric 20XC1-05P4-2W115\u003c\/strong\u003e is part of Franklin's C1 Series of bottom-suction submersible pumps. It is designed to provide dependable high-head performance in filtered effluent and gray water applications while allowing the liquid level in a tank to be drawn down farther than with many conventional submersible pump designs.\u003c\/p\u003e\n\u003cp\u003eThe 20XC1 uses a \u003cstrong\u003efive-stage hydraulic assembly\u003c\/strong\u003e and is rated for approximately \u003cstrong\u003e20 GPM\u003c\/strong\u003e, with a maximum flow rate of approximately \u003cstrong\u003e25 GPM\u003c\/strong\u003e. Its high-head design produces up to approximately \u003cstrong\u003e170 feet of shutoff head\u003c\/strong\u003e, making it well suited for systems with long piping runs, elevation changes, or pressure distribution requirements.\u003c\/p\u003e\n\u003cp\u003eThe pump's bottom-suction design allows for maximum fluid drawdown and does not require a separate flow-induction sleeve. Its internal hydraulic components are designed to pass solids up to \u003cstrong\u003e1\/8 inch\u003c\/strong\u003e without damaging the pump.\u003c\/p\u003e\n\u003cp\u003eStainless-steel construction is used throughout the pump's metal components for corrosion resistance, while engineered thermoplastic hydraulic components help provide quiet operation and dependable performance.\u003c\/p\u003e\n\u003c!-- KEY FEATURES --\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-head 20 GPM design:\u003c\/strong\u003e Provides 20 GPM-class performance for demanding effluent applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e170 ft shutoff head:\u003c\/strong\u003e Five-stage hydraulic design provides substantially more pressure than many conventional effluent pumps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBottom suction:\u003c\/strong\u003e Allows maximum tank drawdown while maintaining reliable pump operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandles 1\/8\" solids:\u003c\/strong\u003e Hydraulic components are designed to allow small suspended solids to pass without damaging the pump.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in check valve:\u003c\/strong\u003e Includes a removable internal check valve for backflow prevention.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1\/2 HP Franklin Electric motor:\u003c\/strong\u003e Designed for dependable residential, commercial, and agricultural pumping applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e115V operation:\u003c\/strong\u003e Single-phase, 2-wire configuration commonly used in residential septic installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless-steel construction:\u003c\/strong\u003e High-grade stainless-steel metal components provide corrosion resistance in demanding water and effluent environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable mounting base:\u003c\/strong\u003e Supplied with a stable 5-inch base for secure installation in tanks and cisterns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-duty power lead:\u003c\/strong\u003e Factory-equipped with a 10-foot, 300V SJOOW jacketed power lead.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- WHAT'S INCLUDED --\u003e\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 Franklin Electric 20XC1-05P4-2W115 submersible pump\u003c\/li\u003e\n\u003cli\u003eFranklin Electric 1\/2 HP, 115V motor\u003c\/li\u003e\n\u003cli\u003eFive-stage high-head hydraulic assembly\u003c\/li\u003e\n\u003cli\u003eBuilt-in removable check valve\u003c\/li\u003e\n\u003cli\u003eRemovable 5-inch mounting base\u003c\/li\u003e\n\u003cli\u003e10-foot SJOOW power lead\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- SPECIFICATIONS --\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0 25px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eFranklin Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eC1 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e20XC1-05P4-2W115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eFranklin Item Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e90302015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eHorsepower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1\/2 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eRated Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e20 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eMaximum Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eApprox. 25 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eMaximum Shutoff Head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e170 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eStages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e115 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e2-Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eSuction Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eBottom Suction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eMaximum Solids\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eDischarge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1-1\/4\" FNPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eCheck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eYes – Removable Built-In Check Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003ePump Body Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eHydraulic Components\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eEngineered Thermoplastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003ePower Lead\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e10 ft SJOOW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003ePump Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eApprox. 26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eBase Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eApprox. 5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eApprox. 17 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c!-- IMPORTANT PUMP SIZING --\u003e\n\u003cdiv style=\"background: #fff8e6; border: 1px solid #eed69a; border-radius: 8px; padding: 18px 20px; margin: 20px 0 25px 0;\"\u003e\n\u003cp style=\"margin: 0 0 8px 0;\"\u003e\u003cstrong\u003eImportant Pump Sizing Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eThe \"20 GPM\" rating identifies the pump's nominal operating range and does not mean the pump will deliver exactly 20 GPM under every installation condition. Actual flow depends on total dynamic head, elevation, pipe size, pipe length, fittings, valves, filters, sprinkler or drip-system requirements, and other restrictions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- 20X EXPLANATION --\u003e\n\u003cdiv style=\"background: #f7f7f7; border: 1px solid #e5e5e5; border-radius: 8px; padding: 18px 20px; margin: 20px 0 25px 0;\"\u003e\n\u003cp style=\"margin: 0 0 8px 0;\"\u003e\u003cstrong\u003eWhat Does \"20X\" Mean?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eThe \u003cstrong\u003e20XC1\u003c\/strong\u003e is Franklin's higher-head version of the C1 20 GPM pump. The standard 20C1 uses a four-stage hydraulic assembly and has approximately 135 feet of shutoff head, while the \u003cstrong\u003e20XC1 uses five stages and provides approximately 170 feet of shutoff head\u003c\/strong\u003e. This makes the 20XC1 better suited for installations requiring additional pressure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- SHIPPING --\u003e\n\u003cdetails style=\"border-top: 1px solid #ddd; padding: 15px 0;\"\u003e\n\u003csummary style=\"cursor: pointer; font-size: 18px;\"\u003e\u003cstrong\u003eShipping Information\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 0 5px 0;\"\u003e\n\u003cp\u003eMost in-stock orders placed before \u003cstrong\u003e2 PM Central Time\u003c\/strong\u003e ship the same business day.\u003c\/p\u003e\n\u003cp\u003eTypical transit time is approximately \u003cstrong\u003e1–4 business days\u003c\/strong\u003e, depending on destination and carrier conditions.\u003c\/p\u003e\n\u003cp\u003eTracking information will be provided when your order ships.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c!-- WARRANTY --\u003e\n\u003cdetails style=\"border-top: 1px solid #ddd; padding: 15px 0;\"\u003e\n\u003csummary style=\"cursor: pointer; font-size: 18px;\"\u003e\u003cstrong\u003eWarranty Information\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 0 5px 0;\"\u003e\n\u003cp\u003eFranklin Electric lists the standard warranty for this model as \u003cstrong\u003e12 months from installation or 24 months from the date of manufacture\u003c\/strong\u003e, subject to the manufacturer's warranty terms and conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement pump installations:\u003c\/strong\u003e When replacing an existing septic effluent pump, SepticStop requires replacement of the pump control float for warranty support. Contact us before ordering if you have questions about the correct float or control configuration for your system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c!-- FAQ --\u003e\n\u003cdetails style=\"border-top: 1px solid #ddd; padding: 15px 0;\"\u003e\n\u003csummary style=\"cursor: pointer; font-size: 18px;\"\u003e\u003cstrong\u003eWhat is the difference between the 20C1 and 20XC1?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 0 5px 0;\"\u003e\n\u003cp\u003eBoth are 1\/2 HP pumps in Franklin Electric's C1 Series. The standard 20C1 is a four-stage pump with approximately 135 feet of shutoff head. The 20XC1 adds a fifth hydraulic stage and increases maximum shutoff head to approximately 170 feet. The 20XC1 is intended for applications that require more pressure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-top: 1px solid #ddd; padding: 15px 0;\"\u003e\n\u003csummary style=\"cursor: pointer; font-size: 18px;\"\u003e\u003cstrong\u003eWhat is a bottom-suction septic pump?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 0 5px 0;\"\u003e\n\u003cp\u003eA bottom-suction pump draws liquid from near the bottom of the pump assembly. This allows the tank to be pumped down to a lower liquid level than many mid-suction designs and is particularly useful in cisterns and pump tanks where maximum drawdown is desired.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-top: 1px solid #ddd; padding: 15px 0;\"\u003e\n\u003csummary style=\"cursor: pointer; font-size: 18px;\"\u003e\u003cstrong\u003eCan this pump be used in a septic spray or pressure-distribution system?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 0 5px 0;\"\u003e\n\u003cp\u003eIt may be used in filtered-effluent pressure applications when its pump curve matches the required flow and total dynamic head of the system. Always verify the hydraulic requirements of the specific septic system before selecting a replacement pump.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-top: 1px solid #ddd; padding: 15px 0;\"\u003e\n\u003csummary style=\"cursor: pointer; font-size: 18px;\"\u003e\u003cstrong\u003eDoes the Franklin 20XC1 have a built-in check valve?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 0 5px 0;\"\u003e\n\u003cp\u003eYes. The C1 Series includes a built-in removable check valve for backflow prevention.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-top: 1px solid #ddd; padding: 15px 0;\"\u003e\n\u003csummary style=\"cursor: pointer; font-size: 18px;\"\u003e\u003cstrong\u003eCan this pump handle solids?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 0 5px 0;\"\u003e\n\u003cp\u003eFranklin Electric states that the C1 Series hydraulic components can pass solids up to approximately \u003cstrong\u003e1\/8 inch\u003c\/strong\u003e. The pump is intended for filtered effluent and gray water applications and should not be used as a raw-sewage or large-solids handling pump.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-top: 1px solid #ddd; padding: 15px 0;\"\u003e\n\u003csummary style=\"cursor: pointer; font-size: 18px;\"\u003e\u003cstrong\u003eDoes 20 GPM mean the pump always produces 20 GPM?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 0 5px 0;\"\u003e\n\u003cp\u003eNo. Actual flow depends on the total dynamic head of the installation. Elevation, pipe diameter, pipe length, fittings, valves, filters, sprinkler heads, drip components, and other restrictions all affect pump performance. Pump selection should be based on the required operating point on the pump curve.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-top: 1px solid #ddd; padding: 15px 0;\"\u003e\n\u003csummary style=\"cursor: pointer; font-size: 18px;\"\u003e\u003cstrong\u003eCan I replace another 1\/2 HP pump with the 20XC1?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 0 5px 0;\"\u003e\n\u003cp\u003ePossibly, but horsepower alone does not determine compatibility. Two 1\/2 HP pumps can have significantly different flow and pressure curves. Verify voltage, required flow, total dynamic head, discharge connection, float controls, and septic-system requirements before substituting a pump.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c!-- SUPPORT CTA --\u003e\n\u003cdiv style=\"background: #f7f7f7; border: 1px solid #e5e5e5; border-radius: 8px; padding: 20px; margin: 25px 0;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eNot Sure Which Septic Pump You Need?\u003c\/h2\u003e\n\u003cp\u003eWe can help you identify the correct replacement before you order. Have the model number from your existing pump, your septic system information, or a photo of the pump label available when you contact us.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eCall:\u003c\/strong\u003e \u003ca href=\"tel:+19408284004\"\u003e940-828-4004\u003c\/a\u003e\u003cbr\u003e\u003cstrong\u003eEmail:\u003c\/strong\u003e \u003ca href=\"mailto:support@septicstop.com\"\u003esupport@septicstop.com\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- COMPLIANCE --\u003e\n\u003cdiv style=\"font-size: 13px; line-height: 1.5; border-top: 1px solid #ddd; padding-top: 15px; margin-top: 25px;\"\u003e\n\u003cstrong\u003eImportant Notice:\u003c\/strong\u003e The customer is responsible for ensuring that pump selection, installation, repair, or replacement complies with all applicable local laws, regulations, permitting requirements, treatment-system approvals, and manufacturer instructions. Pump performance must be matched to the hydraulic requirements of the specific installation. If you are unsure, consult the appropriate local authority or a qualified septic professional.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Franklin Electric","offers":[{"title":"Without Float","offer_id":67753881567426,"sku":null,"price":345.0,"currency_code":"USD","in_stock":true},{"title":"With 10' Mechanical Float","offer_id":67753881600194,"sku":null,"price":379.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0607\/8064\/2498\/files\/franklinc1.jpg?v=1763012226","url":"https:\/\/septicstop.com\/products\/franklin-electric-20xc1-05p4-2w115-1-2-hp-115v-septic-pump","provider":"Septic Stop","version":"1.0","type":"link"}