{"product_id":"fuji-mac-150r2-septic-air-pump-1000-1200-gpd-aerobic-system","title":"Fuji Mac 150R2 Septic Air Pump | 1000-1200 GPD Aerobic System","description":"\u003cp\u003e\u003cspan\u003eFujiMAC 150R2 Septic Air Pump – Mid-to-high capacity linear diaphragm pump for aerobic treatment systems. Quiet, oil-free operation with thermal protection and easy maintenance.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe FujiMAC 150RII can be used to replace many waste water air pumps. This pump is a direct replacement for the common 150 liter per minute pumps found on the majority of residential aerobic treatment systems. It can also be used for larger systems where two or more 150 liter pumps are used. The FujiMAC line of pumps come with the industry standard alarm and air line connections that make it a simple plug and play replacement for competing pumps\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"815\" data-start=\"793\"\u003e\u003cstrong data-end=\"813\" data-start=\"797\"\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1025\" data-start=\"816\"\u003e\n\u003cli data-end=\"904\" data-start=\"816\"\u003e\n\u003cp data-end=\"904\" data-start=\"818\"\u003eDesigned for most 1000GPD -1200GPD residential and light commercial aerobic treatment systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-end=\"1025\" data-start=\"816\"\u003e\n\u003cli data-end=\"962\" data-start=\"905\"\u003e\n\u003cp data-end=\"962\" data-start=\"907\"\u003eSuitable for systems requiring 150 L\/min rated airflow\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-end=\"1025\" data-start=\"816\"\u003e\n\u003cli data-end=\"1025\" data-start=\"963\"\u003e\n\u003cp data-end=\"1025\" data-start=\"965\"\u003eOperates efficiently within the 2.1–3.1 PSI pressure range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1331\" data-start=\"1307\"\u003e\u003cstrong data-end=\"1329\" data-start=\"1311\"\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1705\" data-start=\"1332\"\u003e\n\u003cli data-end=\"1362\" data-start=\"1332\"\u003e\n\u003cp data-end=\"1362\" data-start=\"1334\"\u003e\u003cstrong data-end=\"1352\" data-start=\"1334\"\u003eRated Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e120V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-end=\"1705\" data-start=\"1332\"\u003e\n\u003cli data-end=\"1387\" data-start=\"1363\"\u003e\n\u003cp data-end=\"1387\" data-start=\"1365\"\u003e\u003cstrong data-end=\"1379\" data-start=\"1365\"\u003eFrequency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-end=\"1705\" data-start=\"1332\"\u003e\n\u003cli data-end=\"1419\" data-start=\"1388\"\u003e\n\u003cp data-end=\"1419\" data-start=\"1390\"\u003e\u003cstrong data-end=\"1412\" data-start=\"1390\"\u003ePower Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e115 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-end=\"1705\" data-start=\"1332\"\u003e\n\u003cli data-end=\"1467\" data-start=\"1420\"\u003e\n\u003cp data-end=\"1467\" data-start=\"1422\"\u003e\u003cstrong data-end=\"1451\" data-start=\"1422\"\u003eSuggested Pressure Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.1 – 3.1 PSI\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-end=\"1705\" data-start=\"1332\"\u003e\n\u003cli data-end=\"1500\" data-start=\"1468\"\u003e\n\u003cp data-end=\"1500\" data-start=\"1470\"\u003e\u003cstrong data-end=\"1490\" data-start=\"1470\"\u003eNormal Pressure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.9 PSI\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-end=\"1705\" data-start=\"1332\"\u003e\n\u003cli data-end=\"1554\" data-start=\"1501\"\u003e\n\u003cp data-end=\"1554\" data-start=\"1503\"\u003e\u003cstrong data-end=\"1533\" data-start=\"1503\"\u003eAirflow at Rated Pressure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e150 L\/min (5.3 CFM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-end=\"1705\" data-start=\"1332\"\u003e\n\u003cli data-end=\"1584\" data-start=\"1555\"\u003e\n\u003cp data-end=\"1584\" data-start=\"1557\"\u003e\u003cstrong data-end=\"1573\" data-start=\"1557\"\u003eSound Level:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e41 dB(A)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-end=\"1705\" data-start=\"1332\"\u003e\n\u003cli data-end=\"1607\" data-start=\"1585\"\u003e\n\u003cp data-end=\"1607\" data-start=\"1587\"\u003e\u003cstrong data-end=\"1598\" data-start=\"1587\"\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e18 lbs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-end=\"1705\" data-start=\"1332\"\u003e\n\u003cli data-end=\"1664\" data-start=\"1608\"\u003e\n\u003cp data-end=\"1664\" data-start=\"1610\"\u003e\u003cstrong data-end=\"1637\" data-start=\"1610\"\u003eDimensions (L × W × H):\u003c\/strong\u003e\u003cspan\u003e 11 1\/2\" × 7 1\/4\" × 8 3\/8\"\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-end=\"1705\" data-start=\"1332\"\u003e\n\u003cli data-end=\"1705\" data-start=\"1665\"\u003e\n\u003cp data-end=\"1705\" data-start=\"1667\"\u003e\u003cstrong data-end=\"1686\" data-start=\"1667\"\u003eOutlet OD \/ ID:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1\" OD, 3\/4\" ID\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FujiMAC","offers":[{"title":"Default Title","offer_id":45930487316674,"sku":null,"price":564.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0607\/8064\/2498\/files\/FujiMac-150-Spin-01-01_700x700_244733f0-3b2c-44c3-8e43-4c12bebb4b00.webp?v=1762650898","url":"https:\/\/septicstop.com\/products\/fuji-mac-150r2-septic-air-pump-1000-1200-gpd-aerobic-system","provider":"Septic Stop","version":"1.0","type":"link"}